Process sequence and signal states
For information on the drive's behavior at standstill, refer to the specifications for the "Stop functions" in the "Functions" > "Monitoring functions" > "Control functions" configuration menu of the inverter.
No. | Procedure | PD | Signal states |
|---|---|---|---|
[1] General enable |
| PO 1:0 |
|
| PO 1:1 |
| |
| PO 1:13 |
| |
[1] | Selection of "Synchronous operation" mode | PO 6 |
|
Dynamics parameters are applied (also during ongoing movement) | PO 2 PO 3 PO 4 | Setpoint speed Acceleration Deceleration | |
[1] | Start/stop of the axis | PO 1:7 |
|
[2] to [3] | Setpoint reached | PI 1:7 PI 7 |
|
[3] | Start offset | PO 9:0 |
|
[3] to [4] | Offset active | PI 9:1 |
|
[4] | Offset finished | PI 9:2 |
|
[4] | Actual speed | PI 2 | The drive is synchronous with the master axis again. |