Fieldbus interface
Parameter designation | Description |
|---|---|
Fieldbus configuration | |
Activate fieldbus connection | Activate the fieldbus connection and automatically add the MOVIKIT® fieldbus monitor for monitoring and controlling the fieldbus interface to the IEC project. |
Index: 50000.150 | |
IEC name: – | |
Start address | Start address of the process data in the array of the bus system Default value: 1 |
Index: 50000.151 | |
IEC name: – | |
Basic process data | Amount of process data for the software module without activated "Additional functions" or optional process data |
Index: 50000.159 | |
IEC name: – | |
Optional process data | Additional process data of the activated "Optional process data" |
Index: 50000.163 | |
IEC name: – | |
Process data length | Resulting length of the process data of the software module |
Index: 50000.152 | |
IEC name: – | |
Optional process data | |
MultiAxisController | Activate optional process data for the MultiAxisController and show it in the configuration menu. |
Index: 50000.162 | |
IEC name: – | |
X-direction | |
Payload | Activate specification of the payload in the X-direction. |
Index: 50000.179 | |
IEC name: – | |
P gain position controller | Activate specification of the P gain in the X-direction. |
Index: 50000.180 | |
IEC name: – | |
Anti-sway control enable | Activate setpoint correction selection in the X-direction. |
Index: 50000.181 | |
IEC name: – | |
Skew offset member 2 | Activate specification of skew offset for member 2 in X-direction. |
Index: 50000.198, Bit0 | |
IEC name: – | |
Y-direction | |
Payload | Activate specification of the payload in the Y-direction. |
Index: 50000.182 | |
IEC name: – | |
P gain position controller | Activate specification of the P gain in the Y-direction. |
Index: 50000.183 | |
IEC name: – | |
Skew offset member 2 | Activate specification of skew offset for member 2 in Y-direction. |
Index: 50000.199, Bit0 | |
IEC name: – | |
Number of members of MultiAxisController | Activate specification of the number of members of the software module to obtain additional actual values of the members on the fieldbus interface. |
Index: 50030.240, Bit0 | |
IEC name: – | |
X-direction | Select the number of members of the software module in the X-direction. |
Index: 50000.153 | |
IEC name: – | |
Y-direction | Select the number of members of the software module in the Y-direction. |
Index: 50000.154 | |
IEC name: – | |
Brake test | Activate the process data word of the brake test function. |
Index: 50030.241, Bit0 | |
IEC name: – | |
X-direction | |
Status | Automatically activate the status word of the brake test when the optional process data word is activated. |
Index: 50000.190, Bit0 | |
IEC name: – | |
Measured values | Measured values of the brake test (e.g. the measured distance) of the members of the software module in the X-direction |
Index: 50000.191, Bit0 | |
IEC name: – | |
Y-direction | |
Status | Automatically activate the status word of the brake test when the optional process data word is activated. |
Index: 50000.192, Bit0 | |
IEC name: – | |
Measured values | Measured values of the brake test (e.g. the measured distance) of the members of the software module in the Y-direction |
Index: 50000.193, Bit0 | |
IEC name: – | |
Additional process values of the inverter | Activate additional process values of the inverter. |
Index: 50000.103, Bit0 | |
IEC name: – | |
X-direction | |
Axis 1 – PI 13 – PI 16 | Activate additional process values of the inverter for axis 1 of the software module in the X-direction. |
Index: 50000.194, Bit0 | |
IEC name: – | |
Axis 2 – PI 13 – PI 16 | Activate additional process values of the inverter for axis 2 of the software module in the X-direction. |
Index: 50000.195, Bit0 | |
IEC name: – | |
Y-direction | |
Axis 1 – PI 13 – PI 16 | Activate additional process values of the inverter for axis 1 of the software module in the Y-direction. |
Index: 50000.196, Bit0 | |
IEC name: – | |
Axis 2 – PI 13 – PI 16 | Activate additional process values of the inverter for axis 2 of the software module in the Y-direction. |
Index: 50000.197, Bit0 | |
IEC name: – | |
Advanced settings | |
Decimal places via fieldbus | Define the number of decimal places for position, speed, acceleration, and jerk via fieldbus. |
Index: 50000.155 (position), 50000.156 (speed), 50000.157 (acceleration), 50000.158 (jerk) | |
IEC name: – | |
PROFINET diagnostic alarms INFORMATION: A current device description file must be available for the texts to be displayed correctly. | Send errors and warnings as PROFINET diagnostic alarms so that they can be read in plain text. Default value: Off |
Index: 50000.164, Bit0 | |
IEC name: – | |
Slot number INFORMATION: Only available if PROFINET diagnostic alarms are activated. | Position of the software module on the fieldbus. Slot number 1 corresponds to the 1st freely available slot after the reserved slots for safe communication. For more information, refer to the "Controllers of the MOVI-C® Modular Automation System – Startup with PROFINET/PROFIsafe" manual Default value: 0.000 |
Index: 50000.165 | |
IEC name: – | |
Fieldbus interface | |
Overview of the resulting process data assignment | |