Error responses
The following table describes the error responses to faults:
Error response | Description |
|---|---|
No response | The inverter ignores the event. |
Warning with self reset | The inverter issues a warning message with self-reset. The error is automatically reset after the cause of error is eliminated. |
Warning | The inverter issues a warning message. |
Application stop (with output stage inhibit) | The inverter stops with the deceleration set for the application limit. (Index 8357.13) If n = 0: Brake "applied" and output stage "off". |
Application stop (with output stage inhibit) with self-reset | |
Emergency stop (with output stage inhibit) | The inverter stops with the set emergency stop deceleration. (Index 8357.20) |
Emergency stop (with output stage inhibit) with self-reset | |
Inhibit output stage with self-reset | The output stage is deactivated and the brake is applied. |
Inhibit output stage |
Self-reset means: Eliminating the cause of the error results in acknowledgment of the error. The inverter automatically resumes the operation before the error occurred. The drive can restart automatically.