Fault responses

The following table describes the shut-off responses to faults:

Fault response

Description

No response

The inverter ignores the event.

Warning with self reset

The inverter issues a warning message with self-reset.

Warning

The inverter issues a warning message.

The fault is automatically reset after the cause of fault is eliminated.

Application stop (with output stage inhibit)

The inverter stops with the deceleration set for the application limit (index 8357.13).

If n = 0: Brake "applied" and output stage "off".

Application stop (with output stage inhibit) with self-reset

Emergency stop (with output stage inhibit)

The inverter stops with the set emergency stop deceleration.

(Index 8357.20)

Emergency stop (with output stage inhibit) with self-reset

Inhibit output stage with self-reset

The output stage is deactivated and the brake is applied.

Inhibit output stage

Self-reset means: Eliminating the cause of the fault results in acknowledgment of the fault. The inverter automatically resumes the operation before the fault occurred. The drive can restart automatically.