Configuration of the safe digital inputs for activating the "Muting F-PO" function

WARNING

The active "Muting F-PO" function deactivates the safety sub-functions. This can cause the system to start up immediately.
Severe or fatal injuries.
  • Before activating the "Muting F-PO" function, the user must take organizational measures for the protection of personnel and machinery.

Configure the safe digital inputs with the "Assist CS.." parameterization tool as follows:

  1. Configure a safe digital input using the "Acknowledge error" function.
  2. Configure a safe digital input using the "Muting" function.
  3. In the basic setting of the safety option, set the Selection muting parameter to Encoder error and F-PO.
  4. Set the maximum muting time according to the application's requirements.

In addition, observe the notes in chapter "Muting safe process output data (Muting F-PO)".