Error 149 MOVIKIT® – Controller firmware
Error: 149.0 (9500hex | 38144dec) Description: The speed of at least one cam is invalid. | ||
|---|---|---|
|
| |
Cause | Measure | |
The speed of at least one cam is less than or equal to zero. | Enter a value in the valid range. | |
Error: 149.1 (9501hex | 38145dec) Description: The lower limit speed is invalid. | ||
|---|---|---|
|
| |
Cause | Measure | |
The lower limit speed is greater than the maximum or minimum speed or less than zero. | Enter the value for 'VLimit' in the valid range. | |
Error: 149.2 (9502hex | 38146dec) Description: The order of the speed cams is invalid. | ||
|---|---|---|
|
| |
Cause | Measure | |
The order of the lower and upper cams is incorrect. | Specify the cams in the correct order. | |
Error: 149.3 (9503hex | 38147dec) Description: The sampling cycle is invalid. | ||
|---|---|---|
|
| |
Cause | Measure | |
The sampling cycle is less than or equal to zero. | Enter a value in the valid range. | |
Error: 149.4 (9504hex | 38148dec) Description: Error in the basic profile generator. | ||
|---|---|---|
|
| |
Cause | Measure | |
A calculation error occurred while calculating the travel profile when approaching the speed cams. For more detailed information, refer to the debug variables. | Contact SEW-EURODRIVE Service. | |
Error: 149.5 (9505hex | 38149dec) Description: The specified reference is invalid. | ||
|---|---|---|
|
| |
Cause | Measure | |
Some function blocks require a reference to a variable structure (e.g. the speed cams), which is invalid in this case. | Specify a correct variable structure. | |
Error: 149.6 (9506hex | 38150dec) Description: The target platform is invalid. | ||
|---|---|---|
|
| |
Cause | Measure | |
The function block can only be operated on an SEW controller. | Use a correct controller. | |
Error: 149.7 (9507hex | 38151dec) Description: An error occured in the speed cam profile generator for the x-axis. | ||
|---|---|---|
|
| |
Cause | Measure | |
A calculation error occurred in the x-axis while calculating the travel profile for approaching the speed cams. For more detailed information, refer to the debug variables. | Contact SEW-EURODRIVE Service. | |
Error: 149.8 (9508hex | 38152dec) Description: An error occurred in the speed cam profile generator for the y-axis. | ||
|---|---|---|
|
| |
Cause | Measure | |
A calculation error occurred in the y-axis while calculating the travel profile for approaching the speed cams. For more detailed information, refer to the debug variables. | Contact SEW-EURODRIVE Service. | |
Error: 149.160 (95A0hex | 38304dec) Description: An error occurred while calculating the positional distance between start and end speed. | ||
|---|---|---|
|
| |
Cause | Measure | |
A correct approach of the speed cams requires the point in time for braking. An error occurred during this calculation. | Contact SEW-EURODRIVE. | |
Error: 149.161 (95A1hex | 38305dec) Description: Missing feed enable | ||
|---|---|---|
|
| |
Cause | Measure | |
Optimization cannot be performed due to missing feed enable. | Set the start signal. | |
Error: 149.164 (95A4hex | 38308dec) Description: An error occurred in the profile generator of the x-axis. | ||
|---|---|---|
|
| |
Cause | Measure | |
Optimization is not performed because an error has occurred in the profile generator of the x-axis. | Contact SEW-EURODRIVE Service. | |
Error: 149.165 (95A5hex | 38309dec) Description: An error occurred in the profile generator of the y-axis. | ||
|---|---|---|
|
| |
Cause | Measure | |
Optimization is not performed because an error has occurred in the profile generator of the y-axis. | Contact SEW-EURODRIVE. | |
Error: 149.170 (95AAhex | 38314dec) Description: The speed of the y-axis is lower than the limit speed. | ||
|---|---|---|
|
| |
Cause | Measure | |
There is no synchronous operation as the speed of the y-axis is lower than the limit speed. | Increase the limit speed ('VLimit'). | |
Error: 149.171 (95ABhex | 38315dec) Description: The time base for the y-axis is invalid. | ||
|---|---|---|
|
| |
Cause | Measure | |
There is no synchronous operation as the time base for the y-axis is less than or equal to zero. | Enter a correct time delay ('Delay'). | |
Error: 149.172 (95AChex | 38316dec) Description: The speed of the x-axis is lower than the limit speed. | ||
|---|---|---|
|
| |
Cause | Measure | |
There is no synchronous operation as the speed of the x-axis is lower than the limit speed. | Increase the limit speed ('VLimit'). | |
Error: 149.173 (95ADhex | 38317dec) Description: The time base for the x-axis is invalid. | ||
|---|---|---|
|
| |
Cause | Measure | |
There is no synchronous operation as the time base for the x-axis is less than or equal to zero. | Enter a correct time delay ('Delay'). | |
Error: 149.174 (95AEhex | 38318dec) Description: The speed of the y-axis is lower than the limit speed. | ||
|---|---|---|
|
| |
Cause | Measure | |
X-axis time-defining, y-axis in lowering mode: Optimization is not performed because the speed of the y-axis is lower than the limit speed. | Increase the limit speed ('VLimit'). | |
Error: 149.175 (95AFhex | 38319dec) Description: The stop time is invalid. | ||
|---|---|---|
|
| |
Cause | Measure | |
X-axis time-defining, y-axis in lowering mode: Optimization is not performed because the stop time is zero. | Contact SEW-EURODRIVE. | |
Error: 149.176 (95B0hex | 38320dec) Description: The time base for the y-axis is invalid. | ||
|---|---|---|
|
| |
Cause | Measure | |
X-axis time-defining, y-axis in lowering mode: Optimization is not performed because the time base for the y-axis is less than or equal to zero. | Enter a correct time delay ('Delay'). | |
Error: 149.177 (95B1hex | 38321dec) Description: The speed of the x-axis is lower than the limit speed. | ||
|---|---|---|
|
| |
Cause | Measure | |
Y-axis time-defining and in lifting mode: Optimization is not performed because the speed of the x-axis is lower than the limit speed. | Increase the limit speed ('VLimit'). | |
Error: 149.178 (95B2hex | 38322dec) Description: The time base for the x-axis is invalid. | ||
|---|---|---|
|
| |
Cause | Measure | |
Y-axis time-defining and in lifting mode: Optimization is not performed because the time base for the x-axis is less than or equal to zero. | Enter a correct time delay ('Delay'). | |
Error: 149.179 (95B3hex | 38323dec) Description: The speed of the x-axis is lower than the limit speed. | ||
|---|---|---|
|
| |
Cause | Measure | |
Y-axis time-defining and in lowering mode: Optimization is not performed because the speed of the x-axis is lower than the limit speed. | Increase the limit speed ('VLimit'). | |
Error: 149.180 (95B4hex | 38324dec) Description: The stop time is invalid. | ||
|---|---|---|
|
| |
Cause | Measure | |
Y-axis time-defining and in lowering mode: Optimization is not performed because the stop time is zero. | Contact SEW-EURODRIVE. | |
Error: 149.181 (95B5hex | 38325dec) Description: The time base for the x-axis is invalid. | ||
|---|---|---|
|
| |
Cause | Measure | |
Y-axis time-defining and in lowering mode: Optimization is not performed because the time base for the x-axis is less than or equal to zero. | Enter a correct time delay ('Delay'). | |
Error: 149.240 (95F0hex | 38384dec) Description: Warning: Value transferred to the inverter too large | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
Error: 149.241 (95F1hex | 38385dec) Description: Warning: Value transferred to the inverter too small | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
Error: 149.242 (95F2hex | 38386dec) Description: Inverter warning | ||
|---|---|---|
|
| |
Cause | Measure | |
An inverter warning is present. | Observe the description in MOVISUITE® or the inverter manual. | |