Error 149 MOVIKIT® – Controller firmware

Error: 149.0 (9500hex | 38144dec)

Description: The speed of at least one cam is invalid.

 

 

Cause

Measure

The speed of at least one cam is less than or equal to zero.

Enter a value in the valid range.

Error: 149.1 (9501hex | 38145dec)

Description: The lower limit speed is invalid.

 

 

Cause

Measure

The lower limit speed is greater than the maximum or minimum speed or less than zero.

Enter the value for 'VLimit' in the valid range.

Error: 149.2 (9502hex | 38146dec)

Description: The order of the speed cams is invalid.

 

 

Cause

Measure

The order of the lower and upper cams is incorrect.

Specify the cams in the correct order.

Error: 149.3 (9503hex | 38147dec)

Description: The sampling cycle is invalid.

 

 

Cause

Measure

The sampling cycle is less than or equal to zero.

Enter a value in the valid range.

Error: 149.4 (9504hex | 38148dec)

Description: Error in the basic profile generator.

 

 

Cause

Measure

A calculation error occurred while calculating the travel profile when approaching the speed cams. For more detailed information, refer to the debug variables.

Contact SEW-EURODRIVE Service.

Error: 149.5 (9505hex | 38149dec)

Description: The specified reference is invalid.

 

 

Cause

Measure

Some function blocks require a reference to a variable structure (e.g. the speed cams), which is invalid in this case.

Specify a correct variable structure.

Error: 149.6 (9506hex | 38150dec)

Description: The target platform is invalid.

 

 

Cause

Measure

The function block can only be operated on an SEW controller.

Use a correct controller.

Error: 149.7 (9507hex | 38151dec)

Description: An error occured in the speed cam profile generator for the x-axis.

 

 

Cause

Measure

A calculation error occurred in the x-axis while calculating the travel profile for approaching the speed cams. For more detailed information, refer to the debug variables.

Contact SEW-EURODRIVE Service.

Error: 149.8 (9508hex | 38152dec)

Description: An error occurred in the speed cam profile generator for the y-axis.

 

 

Cause

Measure

A calculation error occurred in the y-axis while calculating the travel profile for approaching the speed cams. For more detailed information, refer to the debug variables.

Contact SEW-EURODRIVE Service.

Error: 149.160 (95A0hex | 38304dec)

Description: An error occurred while calculating the positional distance between start and end speed.

 

 

Cause

Measure

A correct approach of the speed cams requires the point in time for braking. An error occurred during this calculation.

Contact SEW-EURODRIVE.

Error: 149.161 (95A1hex | 38305dec)

Description: Missing feed enable

 

 

Cause

Measure

Optimization cannot be performed due to missing feed enable.

Set the start signal.

Error: 149.164 (95A4hex | 38308dec)

Description: An error occurred in the profile generator of the x-axis.

 

 

Cause

Measure

Optimization is not performed because an error has occurred in the profile generator of the x-axis.

Contact SEW-EURODRIVE Service.

Error: 149.165 (95A5hex | 38309dec)

Description: An error occurred in the profile generator of the y-axis.

 

 

Cause

Measure

Optimization is not performed because an error has occurred in the profile generator of the y-axis.

Contact SEW-EURODRIVE.

Error: 149.170 (95AAhex | 38314dec)

Description: The speed of the y-axis is lower than the limit speed.

 

 

Cause

Measure

There is no synchronous operation as the speed of the y-axis is lower than the limit speed.

Increase the limit speed ('VLimit').

Error: 149.171 (95ABhex | 38315dec)

Description: The time base for the y-axis is invalid.

 

 

Cause

Measure

There is no synchronous operation as the time base for the y-axis is less than or equal to zero.

Enter a correct time delay ('Delay').

Error: 149.172 (95AChex | 38316dec)

Description: The speed of the x-axis is lower than the limit speed.

 

 

Cause

Measure

There is no synchronous operation as the speed of the x-axis is lower than the limit speed.

Increase the limit speed ('VLimit').

Error: 149.173 (95ADhex | 38317dec)

Description: The time base for the x-axis is invalid.

 

 

Cause

Measure

There is no synchronous operation as the time base for the x-axis is less than or equal to zero.

Enter a correct time delay ('Delay').

Error: 149.174 (95AEhex | 38318dec)

Description: The speed of the y-axis is lower than the limit speed.

 

 

Cause

Measure

X-axis time-defining, y-axis in lowering mode: Optimization is not performed because the speed of the y-axis is lower than the limit speed.

Increase the limit speed ('VLimit').

Error: 149.175 (95AFhex | 38319dec)

Description: The stop time is invalid.

 

 

Cause

Measure

X-axis time-defining, y-axis in lowering mode: Optimization is not performed because the stop time is zero.

Contact SEW-EURODRIVE.

Error: 149.176 (95B0hex | 38320dec)

Description: The time base for the y-axis is invalid.

 

 

Cause

Measure

X-axis time-defining, y-axis in lowering mode: Optimization is not performed because the time base for the y-axis is less than or equal to zero.

Enter a correct time delay ('Delay').

Error: 149.177 (95B1hex | 38321dec)

Description: The speed of the x-axis is lower than the limit speed.

 

 

Cause

Measure

Y-axis time-defining and in lifting mode: Optimization is not performed because the speed of the x-axis is lower than the limit speed.

Increase the limit speed ('VLimit').

Error: 149.178 (95B2hex | 38322dec)

Description: The time base for the x-axis is invalid.

 

 

Cause

Measure

Y-axis time-defining and in lifting mode: Optimization is not performed because the time base for the x-axis is less than or equal to zero.

Enter a correct time delay ('Delay').

Error: 149.179 (95B3hex | 38323dec)

Description: The speed of the x-axis is lower than the limit speed.

 

 

Cause

Measure

Y-axis time-defining and in lowering mode: Optimization is not performed because the speed of the x-axis is lower than the limit speed.

Increase the limit speed ('VLimit').

Error: 149.180 (95B4hex | 38324dec)

Description: The stop time is invalid.

 

 

Cause

Measure

Y-axis time-defining and in lowering mode: Optimization is not performed because the stop time is zero.

Contact SEW-EURODRIVE.

Error: 149.181 (95B5hex | 38325dec)

Description: The time base for the x-axis is invalid.

 

 

Cause

Measure

Y-axis time-defining and in lowering mode: Optimization is not performed because the time base for the x-axis is less than or equal to zero.

Enter a correct time delay ('Delay').

Error: 149.240 (95F0hex | 38384dec)

Description: Warning: Value transferred to the inverter too large

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error: 149.241 (95F1hex | 38385dec)

Description: Warning: Value transferred to the inverter too small

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error: 149.242 (95F2hex | 38386dec)

Description: Inverter warning

 

 

Cause

Measure

An inverter warning is present.

Observe the description in MOVISUITE® or the inverter manual.