Error 128 MOVIKIT® – Robotics additional functions

Error: 128.0 (8000hex | 32768dec)

Description: Internal error

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error: 128.32 (8020hex | 32800dec)

Description: Interface not linked

 

 

Cause

Measure

The library version does not match the code-generated IEC project.

– In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project".

– In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project".

Error: 128.33 (8021hex | 32801dec)

Description: "SEW_IRobLang" interface not connected

 

 

Cause

Measure

The library version does not match the code-generated IEC project.

– In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project".

– In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project".

Error: 128.34 (8022hex | 32802dec)

Description: "SEW_ITouchProbeProfile" interface not connected

 

 

Cause

Measure

The library version does not match the code-generated IEC project.

– In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project".

– In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project".

Error: 128.35 (8023hex | 32803dec)

Description: "SEW_ITransform" interface not connected

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

The library version does not match the code-generated IEC project.

– In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project".

– In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project".

Error: 128.36 (8024hex | 32804dec)

Description: "SEW_IExecuteEvent" interface not connected

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

The library version does not match the code-generated IEC project.

– In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project".

– In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project".

Error: 128.37 (8025hex | 32805dec)

Description: Connection of the requested interface not used

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error: 128.38 (8026hex | 32806dec)

Description: Trigger source outside permitted range

 

 

Cause

Measure

The specified trigger source when registering the Touchprobe is invalid.

Select valid "SRL_BOOLVAR" for the trigger source (value between 1 and 100).

Error: 128.39 (8027hex | 32807dec)

Description: Invalid mode while registering the Touchprobe

 

 

Cause

Measure

The selected execution mode is outside the permitted value range.

Select single mode (value = 1) or multiple mode (value = 2).

Error: 128.40 (8028hex | 32808dec)

Description: Invalid edge when registering the Touchprobe

 

 

Cause

Measure

The selected edge is outside the permitted range.

Select one of the following values for the edge evaluation:

– Rising edges (value = 1)

– Falling edges (value = 2)

– Rising and falling edges (value = 3).

Error: 128.41 (8029hex | 32809dec)

Description: Invalid measuring direction when registering the Touchprobe

 

 

Cause

Measure

The selected measuring direction is outside the permitted range.

Select one of the following values for the measuring direction:

– X direction (value = 1)

– Y direction (value = 2)

– Z direction (value = 3).

Error: 128.42 (802Ahex | 32810dec)

Description: Invalid trigger source variable when registering the Touchprobe

 

 

Cause

Measure

The selected trigger source is outside the permitted range.

Select valid "SRL_BOOLVAR" (value between 1 and 100) for the trigger source.

Error: 128.43 (802Bhex | 32811dec)

Description: Several Touchprobe commands registered simultaneously

 

 

Cause

Measure

A Touchprobe event is registered while another Touchprobe event is active.

Deactivate active Touchprobe event before activating a new Touchprobe event.

Error: 128.44 (802Chex | 32812dec)

Description: Counter of the activated Touchprobe event reports overflow

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error: 128.45 (802Dhex | 32813dec)

Description: Counter of the active Touchprobe event reports overflow

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error: 128.46 (802Ehex | 32814dec)

Description: Program stop required

 

 

Cause

Measure

This error requires a program stop. The error can only be reset after a program stop

Stop program.

Error: 128.47 (802Fhex | 32815dec)

Description: Transformation of axis positions to room position failed

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error: 128.48 (8030hex | 32816dec)

Description: Failed to execute Touchprobe event

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error: 128.49 (8031hex | 32817dec)

Description: Incorrect order of SRL commands

 

 

Cause

Measure

The Continue command may only be interpreted after registering a Touchprobe command.

Adjust the order of the SRL commands of the program.

Error: 128.50 (8032hex | 32818dec)

Description: Internal error

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error: 128.51 (8033hex | 32819dec)

Description: Positioning in multiple trigger mode not possible

 

 

Cause

Measure

Touchprobe is deactivated because positioning was triggered even though the multiple trigger mode is set. Positioning is only possible in single trigger mode.

– No action required.

– Adjust the robot program if necessary.

Error: 128.52 (8034hex | 32820dec)

Description: Maximum value of the Touchprobe counter reached

 

 

Cause

Measure

The counter value has reached the upper limit of the data type and the Touchprobe counter is broken to 0.

No measure required.