Error 116 MOVIKIT® – MultiMotion electronic cam
Error: 116.0 (7400hex | 29696dec) Description: Parameters of the curve segments not found | ||
|---|---|---|
|
| |
Cause | Measure | |
The required curve data is missing completely or individual parameters are not available. | Check the curves in the CAM Editor tool. Next, load the data to the controller using the menu command [PC -> device] in MOVISUITE®. | |
Error: 116.1 (7401hex | 29697dec) Description: Error reading curve file | ||
|---|---|---|
|
| |
Cause | Measure | |
The required configuration data are missing completely or individual parameters are not available. | – Check the configuration of the individual operating modes. – In MOVISUITE® in the parameter setting of the controller under [Data management], download the data by clicking "Update configuration data". | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.2 (7402hex | 29698dec) Description: Limit for segments/curve exceeded | ||
|---|---|---|
|
| |
Cause | Measure | |
The number of curve segments read is outside the permitted range of 1 – 20. | – Reduce the number of segments in the curve. – Change segment boundary. | |
Error: 116.3 (7403hex | 29699dec) Description: "ICurveFileList" interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.4 (7404hex | 29700dec) Description: "ICamSegment" interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.5 (7405hex | 29701dec) Description: "IAxisConfig" interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.6 (7406hex | 29702dec) Description: "ICammingProfile" interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.7 (7407hex | 29703dec) Description: "ICamDescription" interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.8 (7408hex | 29704dec) Description: "IUnitCalculations" interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.9 (7409hex | 29705dec) Description: "IConfigDataHandler" interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.10 (740Ahex | 29706dec) Description: "IInterpolationModeSelection" interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.11 (740Bhex | 29707dec) Description: No master axis connected | ||
|---|---|---|
|
| |
Cause | Measure | |
Master axis not configured in MOVISUITE®. | – Check the configuration of the electronic cam in MOVISUITE®. – In MOVISUITE® in the parameter setting of the controller under [Data management], download the data by clicking "Update configuration data". | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.12 (740Chex | 29708dec) Description: No cam description found | ||
|---|---|---|
|
| |
Cause | Measure | |
The required curve data is missing completely or individual parameters are not available. | Check the curves in the CAM Editor tool. Next, load the data to the controller using the menu command [PC -> device] in MOVISUITE®. | |
Limit for the number of segments per curve exceeded. | – Reduce the number of segments in the curve. – Change segment boundary. | |
MOVIKIT® MultiMotion Camming add-on Interpolation not activated in MOVISUITE®. | – Activate add-on. – In MOVISUITE® in the parameter setting of the controller under [Data management], download the data by clicking "Update configuration data". | |
The required configuration data are missing completely or individual parameters are not available. | – Check the configuration of the individual operating modes in MOVISUITE®. – In MOVISUITE® in the parameter setting of the controller under [Data management], download the data by clicking "Update configuration data". | |
The license required for the function is missing or invalid. | Purchase the required license. Contact your responsible SEW-EURODRIVE sales partner for this purpose. | |
The internal profile generator detected an error. | Observe the error message of the subcomponent. Identify the exact cause of this error message and take the appropriate measures to eliminate the error. | |
Internal error | Contact SEW-EURODRIVE Service. | |
Master axis not configured in MOVISUITE®. | – Check the configuration of the electronic cam in MOVISUITE®. – In MOVISUITE® in the parameter setting of the controller under [Data management], download the data by clicking "Update configuration data". | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.13 (740Dhex | 29709dec) Description: "ICamDescription" and "ICamDescriptionScheduler" interfaces not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.14 (740Ehex | 29710dec) Description: "IConfigData" interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.15 (740Fhex | 29711dec) Description: Interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error. One of the interfaces is not linked. | Contact SEW-EURODRIVE Service. | |
Error: 116.16 (7410hex | 29712dec) Description: "IPointsListSpline" interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.17 (7411hex | 29713dec) Description: "IPointList" interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.18 (7412hex | 29714dec) Description: "ICamDescriptionSchedulerCyclic" interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.19 (7413hex | 29715dec) Description: "ICamDescriptionCyclic" interface not linked | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.20 (7414hex | 29716dec) Description: MOVIKIT® MultiMotion Camming add-on Interpolation not active | ||
|---|---|---|
|
| |
Cause | Measure | |
MOVIKIT® MultiMotion Camming add-on Interpolation not activated in MOVISUITE®. | – Activate add-on. – In MOVISUITE® in the parameter setting of the controller under [Data management], download the data by clicking "Update configuration data". | |
The library version does not match the code-generated IEC project. | – In the parameter setting of the controller in MOVISUITE® under [IEC project], update the project by clicking "Update IEC project". – In MOVISUITE®, activate the parameter "Update/recreate software modules" in the parameter setting of the controller under [IEC project] and perform the project update by "Update IEC project". | |
Error: 116.21 (7415hex | 29717dec) Description: License missing for MOVIKIT® MultiMotion Camming | ||
|---|---|---|
|
| |
Cause | Measure | |
The license required for the function is missing or invalid. | Contact SEW-EURODRIVE Service. | |
Error: 116.22 (7416hex | 29718dec) Description: License missing for MOVIKIT® MultiMotion Camming add-on Interpolation | ||
|---|---|---|
|
| |
Cause | Measure | |
The license required for the function is missing or invalid. | Contact SEW-EURODRIVE Service. | |
Error: 116.23 (7417hex | 29719dec) Description: Profile generation system error | ||
|---|---|---|
|
| |
Cause | Measure | |
The internal profile generator detected an error. | Observe the error message of the subcomponent. Identify the exact cause of this error message and take the appropriate measures to eliminate the error. | |
Error: 116.24 (7418hex | 29720dec) Description: Invalid "eTransitionType" | ||
|---|---|---|
|
| |
Cause | Measure | |
The setting for the "eTransitionType" variable is not permitted. | Use another setting. | |
Error: 116.25 (7419hex | 29721dec) Description: Invalid "eStartMode" | ||
|---|---|---|
|
| |
Cause | Measure | |
The setting for the "eStartMode" variable is not permitted. | Use another setting. | |
Error: 116.26 (741Ahex | 29722dec) Description: Invalid "eStopMode" | ||
|---|---|---|
|
| |
Cause | Measure | |
The setting for the "eStopMode" variable is not permitted. | Use another setting. | |