Error 80 charging management
Error: 80.10 (500Ahex | 20490dec) Description: Deep discharge – prewarning | ||
|---|---|---|
|
| |
Cause | Measure | |
State of charge not determined correctly. | Perform state of charge adjustment. | |
Storage unit discharged too deeply. | Charge the storage unit. | |
Error: 80.11 (500Bhex | 20491dec) Description: Deep discharge | ||
|---|---|---|
|
| |
Cause | Measure | |
State of charge not determined correctly. | Perform state of charge adjustment. | |
Storage unit discharged too deeply. | Charge the storage unit. | |
Error: 80.12 (500Chex | 20492dec) Description: Deep discharge (charge quantity) | ||
|---|---|---|
|
| |
Cause | Measure | |
Storage unit discharged too deeply. | Charge the storage unit. | |
Error: 80.13 (500Dhex | 20493dec) Description: State of charge adjustment not performed | ||
|---|---|---|
|
| |
Cause | Measure | |
Time period for state of charge adjustment exceeded. | Perform state of charge adjustment. | |
Charging interval for state of charge adjustment exceeded. | Perform state of charge adjustment. | |
Error: 80.15 (500Fhex | 20495dec) Description: Balancing not performed | ||
|---|---|---|
|
| |
Cause | Measure | |
Time period for state of charge adjustment exceeded. | Perform state of charge adjustment. | |
Charging interval for state of charge adjustment exceeded. | Perform state of charge adjustment. | |
Error: 80.17 (5011hex | 20497dec) Description: Dynamic charging current limit exceeded – prewarning | ||
|---|---|---|
|
| |
Cause | Measure | |
Storage unit briefly overloaded. | Reduce the load. | |
Error: 80.18 (5012hex | 20498dec) Description: Dynamic charging current limit exceeded | ||
|---|---|---|
|
| |
Cause | Measure | |
Storage unit permanently overloaded. | Reduce the load. | |
Error: 80.19 (5013hex | 20499dec) Description: Dynamic discharging current exceeded – prewarning | ||
|---|---|---|
|
| |
Cause | Measure | |
Storage unit briefly overloaded. | Reduce the load. | |
Error: 80.20 (5014hex | 20500dec) Description: Dynamic discharging current exceeded | ||
|---|---|---|
|
| |
Cause | Measure | |
Storage unit permanently overloaded. | Reduce the load. | |
Error: 80.21 (5015hex | 20501dec) Description: State of charge adjustment aborted | ||
|---|---|---|
|
| |
Cause | Measure | |
State-of-charge adjustment (full charge) was aborted, e.g. due to excessive storage unit temperatures. | Perform a state-of-charge adjustment after an idle period. | |
Error: 80.22 (5016hex | 20502dec) Description: Warning threshold state of charge undershot | ||
|---|---|---|
|
| |
Cause | Measure | |
The storage unit has been discharged below the warning threshold. | Charge the storage unit. | |
Error: 80.23 (5017hex | 20503dec) Description: Switch-off threshold state of charge undershot | ||
|---|---|---|
|
| |
Cause | Measure | |
The storage unit has been discharged below the switch-off threshold. | Charge the storage unit. | |
Error: 80.24 (5018hex | 20504dec) Description: Charge reserve timeout | ||
|---|---|---|
|
| |
Cause | Measure | |
No enable given for the charge reserve within the timeout time. | – Grant enable for the charge reserve. or – Charge the storage unit. | |
Error: 80.25 (5019hex | 20505dec) Description: Determining aging condition aborted | ||
|---|---|---|
|
| |
Cause | Measure | |
Determining state of health (SoH) was aborted. | Determine state of health again, e.g. as part of balancing. | |
Error: 80.26 (501Ahex | 20506dec) Description: State of health (SoH) low | ||
|---|---|---|
|
| |
Cause | Measure | |
The determined state of health (SoH) is too low. | Replace the storage unit. | |
Error: 80.27 (501Bhex | 20507dec) Description: State of charge adjustment mode not defined | ||
|---|---|---|
|
| |
Cause | Measure | |
The "State of charge adjustment mode" parameter was set to "disabled". | Define another setting for the parameter. | |
No mode or several modes are set at the same time in the control word "Control bits – state of charge adjustment mode", for example: – Monitored deep discharge – Complete charge | Set only one mode. | |