Error 17 Internal processor error

Error: 17.6 (1106hex | 4358dec)

Description: Watchdog error

 

 

Cause

Measure

CPU watchdog detected an error.

– Switch the devices off and on again.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Error: 17.7 (1107hex | 4359dec)

Description: Exception

 

 

Cause

Measure

Internal trap in CPU.

– Switch the device off and on again.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Error: 17.8 (1108hex | 4360dec)

Description: Non-volatile data not loaded

 

 

Cause

Measure

The CPU has been restarted several times without firmware being fully initialized. The non-volatile data is not loaded, the default values remain active.

– Acknowledge the fault.

– Check the voltage supply.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Error: 17.9 (1109hex | 4361dec)

Description: Internal error

 

 

Cause

Measure

A fault was detected by the functionally safe component of the device.

Replace the device.