Procedure

  1. Observe the information on cooling water temperature and flow rate. You can find it in the order documents.
  2. The water cooling cover is not equipped with a water drain. In the event of repair work, install a drain on the cooling water outlet to ensure proper draining of the cooling water.
  3. Connect the water cooling cover to the existing cooling circuit. The direction of flow is user-defined. Two bores with pipe threads are available to connect to the cooling circuit.
    • Sizes X100 – 170: G3/8"
    • Sizes X180 – 210: G1/2"