Fault 7 DC link

Fault: 7.1 (0701hex | 1793dec)

Description: DC link overvoltage

 

Response: Remote – critical fault

Cause

Measure

The maximum permitted DC link voltage limit was exceeded.

– Check the connection of the braking resistor.

– Decrease deceleration.

– Check the configuration of the braking resistor (resistance value).

Fault: 7.11 (070Bhex | 1803dec)

Description: DC link overvoltage at rectifier

 

Response: Remote – critical fault with self-reset

Cause

Measure

The fault can be caused as follows:

– The maximum permitted DC link voltage limit of the rectifier was exceeded.

– The AC voltage component of the DC link voltage is too high.

– Check the system and nearby devices for ground faults.

– Check the quality of the supply system (line voltage distortion).

– Check the line voltage.