Size 3 with MOVILINK® DDI interface (MPX23A-..-CO-C)
The following figure shows the plug connector positions for MOVIPRO® technology size 3 with MOVILINK® DDI interface:

[A] | → | Connections for Safety technology and external encoder |
[B] | → | Connections for Inputs and outputs |
[C] | → | Connections for Communication |
[1] | X4142 | Connection for Engineering interface, optional |
[2] | X2303 | Connection for Braking resistor |
[3] | X1213 | AC 400 V input/DC 24 V supply for interface box |
X1214 | ||
[4] | X2107 | Connection for Motor with MOVILINK® DDI |
X2710 | Connection for Motor with MOVILINK® DDI and BG1Z brake control | |
[5] | X5111 | Connection for External fan, only for devices with a nominal output current of 32 A |
[6] | – | External fan, optional, only for devices with a nominal output current of 32 A |