Lifting applications
Perform the following additional steps before starting up the lifting applications:
- Observe the following information.
- Do not use the "Release brake/deactivate DynaStop® for FCB01" function in lifting devices or applications with loads that may potentially fall down. Disable the function as follows:
- Disable the function via parameter Functions > Drive functions > FCB01 Output stage inhibit > Release brake/deactivate DynaStop® for FCB01 – enable = "0" (No).
- Operate the inverter in the ELSM® control mode only in applications with horizontal materials handling technology.
- In the MOVISUITE® engineering software, configure the parameters according to the lifting application requirements and its safety assessment.
- Set the parameter Functions > Drive functions > FCB01 Output stage inhibit > Apply brake with STO = "1" (Yes).
- Set parameter Integrator mode (8404.9) = "0" (hold). Path: Optimization AS1/2 > Set controller dynamics > Advanced settings.