Fault 81 Storage unit

Subfault: 81.1

Description: Overvoltage

 

Response: Output stage inhibit

Cause

Measure

Maximum storage voltage exceeded.

Discharge the storage unit.

Subfault: 81.2

Description: Overvoltage – prewarning

 

Response: Warning

Cause

Measure

Prewarning threshold for maximum storage voltage exceeded.

Discharge the storage unit.

Subfault: 81.3

Description: Undervoltage

 

Response: Warning

Cause

Measure

Minimum storage voltage undershot.

Charge the storage unit.

Subfault: 81.4

Description: Undervoltage – prewarning

 

Response: Warning

Cause

Measure

Prewarning threshold for minimum storage voltage undershot.

Charge the storage unit.

Subfault: 81.7

Description: Overcurrent in discharging direction

 

Response: Output stage inhibit

Cause

Measure

Storage unit permanently overloaded.

Reduce the load.

Subfault: 81.10

Description: Overcurrent in charging direction

 

Response: Output stage inhibit

Cause

Measure

Storage unit permanently overloaded.

Reduce the load.

Subfault: 81.12

Description: Overtemperature (electronics)

 

Response: Warning

Cause

Measure

Storage unit overloaded.

Reduce the load.

Subfault: 81.13

Description: Overtemperature (storage cells) – prewarning

 

Response: Warning

Cause

Measure

Storage unit overloaded.

Reduce the load.

Subfault: 81.14

Description: Overtemperature (storage cells)

 

Response: Emergency stop + output stage inhibit

Cause

Measure

Storage unit overloaded.

Reduce the load.

Subfault: 81.19

Description: External fault

 

Response: Emergency stop + output stage inhibit

Cause

Measure

An energy module in a storage unit detected a critical fault.

Check the energy storage modules for faults.

Subfault: 81.24

Description: General fault

 

Response: Output stage inhibit

Cause

Measure

Storage unit signaled general fault.

Check the condition of the storage unit.

Subfault: 81.25

Description: Undertemperature (storage cells)

 

Response: Output stage inhibit

Cause

Measure

Ambient temperature too low.

Heat the surroundings.

Subfault: 81.26

Description: Undertemperature (storage cells) – prewarning

 

Response: Warning

Cause

Measure

Ambient temperature too low.

Heat the surroundings.

Subfault: 81.27

Description: Internal notification

 

Response: Output stage inhibit

Cause

Measure

Storage unit signaled internal fault.

Check the condition of the storage unit.

Subfault: 81.28

Description: Overcurrent

 

Response: Output stage inhibit

Cause

Measure

Storage unit permanently overloaded.

Reduce the load.

Subfault: 81.29

Description: Critical fault

 

Response: Output stage inhibit

Cause

Measure

Storage unit signaled critical fault.

Check the condition of the storage unit.

Subfault: 81.30

Description: Manufacturer-specific fault

 

Response: Output stage inhibit

Cause

Measure

Storage unit detected manufacturer-specific fault.

Check the condition of the storage unit.

Subfault: 81.33

Description: Manufacturer-specific warning

 

Response: Warning

Cause

Measure

Storage unit reported manufacturer-specific warning.

Check the condition of the storage unit.