MOVIKIT® PowerMode

Overview of the functions of MOVIKIT® PowerMode:

  • Recording power and energy data
    • Communication with Power and Energy Solutions devices (MDP92A, MDE90A) for detecting power and energy data at the connection point to the power grid and to the energy storage unit
    • Communication with MOVIDRIVE® modular for determining the power demand of the connected application
    • Determining the total power and energy balance including AC loads
  • Managing the DC link
    • Specifying voltage setpoints of the DC link during operation
    • Configuring a maximum power output to the DC link during operation
    • Calculating the power of the DC link capacity
    • Use as a central node for supply and output power
    • Discharging the DC link capacity
  • Managing the AC connection
    • Limiting the grid power (peak shaving)
    • Measuring phase-to-phase voltages
    • Calculating the current consumption of the individual line phases (applies only to symmetrical three-phase supply systems)
    • Phase and power failure detection and calculation of the remaining system runtime
  • Managing the energy storage unit
    • Providing storage-relevant data (temperature, voltage, overvoltage detection)
    • Evaluating diagnostic interfaces of selected energy storage units available on the market
    • Aggregating data when using storage units consisting of several modules
    • Transmitting the storage state to the application program for further processing
    • Discharging energy storage units
    • Synchronizing, connecting and disconnecting disconnectable energy storage units
    • Monitoring and controlling single- or multi-stage fuse concepts for specific energy storage types or sizes