Process input data
The following table shows the process input data from the inverter to the higher-level controller for control via fieldbus with 8 process data words:
Word | Bit | Function | |
|---|---|---|---|
PI 1 | Status word | 0 | "1": Device is ready for operation and no error is active in the software module. |
1 | Reserved. | ||
2 | "1": Output stage enable. | ||
3 | "1": Power supply OK. MDE90A: The "Power supply OK" signal is transmitted by the power supply module (module bus master). The power supply is sufficient for operation. | ||
4 | "1": Supply active (B -> A). The device feeds a current ≥ 1 A into the DC link and the output stage of the device is enabled. | ||
5 | "1": Supply active (A -> B). The device feeds a current > 1 A into the connected energy storage unit and the output stage of the device is enabled. | ||
6 | Energy storage unit connected. "1": The energy storage unit is connected to the DC link (in case of connectable energy storage units). The software module has successfully completed a corresponding synchronization process and has connected the storage unit. | ||
7 | "1": Setpoint reached – the active operating mode signals that the setpoint has been reached.
| ||
8 | "1": Error. | ||
9 | "1": Warning. | ||
10 |
(Applies only to the MDE90A device.) | ||
11 | "1": State of charge low. The state of charge has a value below the defined operating range. | ||
12 | "1": State of charge high. The state of charge has a value above the specified operating range. | ||
13 | "1": Current limit active. A current limit is set by the software module and restricts the power supply. INFORMATION: The operation of connected axes should be set. | ||
14 | "1": Standby mode active. | ||
15 | MOVIKIT® Handshake Out. | ||
PI 2 | Actual value state of charge |
| |
PI 3 | Status Error-suberror |
| |
PI 4 | Actual value charging power |
| |
PI 5 | Digital inputs INFORMATION: The digital inputs might be disabled by MOVIKIT® operating modes. | 0 | DI 00 |
1 | DI 01 | ||
2 | DI 02 | ||
3 | MDP92A: Test bit of the braking resistor (X7.2) MDE90A: DI 03 | ||
4 | Reserved | ||
5 | Reserved | ||
6 | Reserved | ||
7 | Reserved | ||
8 | Reserved | ||
9 | Reserved | ||
10 | Reserved | ||
11 | Reserved | ||
12 | Reserved | ||
13 | Reserved | ||
14 | Reserved | ||
15 | Reserved | ||
PI 6 | Actual application mode | Active operating mode (see PO 6) | |
PI 7 | Actual value voltage | Actual voltage A-side devices [±10-1 V] | |
PI 8 | Actual value voltage | Actual voltage B-side devices [±10-1 V] | |