Process output data

Word

Bit

Function

PO 1

Control word

0

Enable/emergency stop

1

Enable/application stop

2

Reserved

3

Release brake (without enable)

4

Jog positive

5

Jog negative

6

Apply relative position

7

Start/stop with fieldbus ramp

8

Error reset

9

Reserved

10

Activate drive train 2

11

Reserved

12

Deactivate software limit switches

13

Activate output stage inhibit

14

Activate standby mode

15

MOVIKIT® Handshake In

PO 2

Setpoint speed

0 – 15

User unit

PO 3

Setpoint acceleration

0 – 15

User unit

PO 4

Setpoint deceleration

0 – 15

User unit

PO 5

Digital outputs

0

DO 00 / DIO 01 (output)

1

DO 01 / DIO 02 (output)

3

DO 03

PO 6

Setpoint application mode

0 – 15

Operating mode. See chapter Operating modes

PO 7

Target position high word

0 – 15

User unit

PO 8

Target position low word

0 – 15

User unit

PO 9

Application control word

0

Interrupt current curve profile and perform instant cut.

INFORMATION: The signal is only evaluated if the axis is in the rest position with a target speed of 0.

1

On-the-fly synchronization/desynchronization without interruption.

INFORMATION: The master must move in positive direction of rotation. If this bit is not activated, synchronize and desynchronize occur directly. This requires the master to be in an idle state.

2

Reset cut counter

3

Activate print mark controller (only possible in operating mode 1402)

4-15

Reserved

PO 10

Nominal cut length
high word

 

High word of the nominal cut length of products cut by the rotary knife in [mm] with two decimal places.

PO 11

Nominal cut length
low word

 

Low word of the nominal cut length of products cut by the rotary knife in [mm] with two decimal places

PO 12

Number of tools

 

Number of tools on the rotary knife

PO 13

Knife diameter

 

Diameter of the rotary knife in [mm] with two decimal places

PO 14

Synchronous angle

 

Angle in [degrees] at which the rotary knife moves in sync with the product with two decimal places

PO 15

Sync correction

 

Setpoint deviation from synchronism in the synchronous angle in [0.01%] steps.

Example: PO 14 = 100 => 1% oversynchronous. PO 14 = -100 => 1% undersynchronous