Digital outputs

Unit

Specification

Quantity

4

Design

in accordance with IEC 61131-2

Response time

µs

175 plus cycle time

Maximum output current

mA

50

Capacitive load

nF

≤ 300

Inductive load

Not permitted

Protection device

Short-circuit proof, protected against external voltage DC 0 – 30 V

X52:6 to 9

DO10 – DO13: Selection option, see parameter menu