Fault 119 MOVIKIT® – MultiMotion additional functions

Fault: 119.0 (7700hex | 30464dec)

Description: Interface not linked

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Fault: 119.1 (7701hex | 30465dec)

Description: Invalid input parameter

 

 

Cause

Measure

One or several input parameters are invalid.

Check that the input parameters are within the limits.

Fault: 119.2 (7702hex | 30466dec)

Description: Error reading configuration file

 

 

Cause

Measure

Configuration file for "AntiSlosh" add-on not found on memory card of controller.

In MOVISUITE®, download the data in the parameter setting of the controller under [Data management] by clicking "Update configuration data".

Fault: 119.3 (7703hex | 30467dec)

Description: Invalid configuration parameter

 

 

Cause

Measure

A configuration parameter for calculating the AntiSlosh profile is invalid.

Select the configuration parameters of the AntiSlosh profile within the limits.

Fault: 119.4 (7704hex | 30468dec)

Description: Invalid cam description

 

 

Cause

Measure

The cam description must be empty before calling the AntiSlosh constructor.

Delete the cam description before calling the AntiSlosh constructor.

Fault: 119.31 (771Fhex | 30495dec)

Description: Undefined error

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.