Fault 110 MOVIKIT® – Communication

Fault: 110.64 (6E40hex | 28224dec)

Description: Parameter request error

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error during parameter request of controller to inverter.

Check whether the parameter to be read/written is present in the inverter.

Fault: 110.65 (6E41hex | 28225dec)

Description: Error responding to parameter request

 

 

Cause

Measure

Error in response of inverter to parameter request of controller.

Contact SEW-EURODRIVE Service.

Fault: 110.66 (6E42hex | 28226dec)

Description: Link of logical device missing

 

 

Cause

Measure

No reference to device (logical device) passed to software function.

Transfer the logical device to the software function.