OUT

Variable name

Description

xConnected

Data type: BOOL

  • TRUE: Communication connection (SBusPLUS) active
  • FALSE: Communication connection (SBusPLUS) not active

eInverterMode

Data type: ENUMERATION

Active FCB or active operating mode.

  • FCB_STANDARD: 0
    Default FCB
  • FCB_OUTPUT_STAGE_TEST: 22
    Output stage test
  • FCB_OUTPUT_STAGE_INHIBIT: 51
    Output stage inhibit activated
  • FCB_HOLD_PRECHARGING: 53
    Hold precharge
  • FCB_SUPPLY_AND_REGENERATIVE_MODE: 58
    Supply and regenerative mode

wDigitalInputs

Data type: WORD

State of the digital inputs

usiErrorID

Data type: USINT

Error ID

usiErrorSubID

Data type: USINT

Suberror ID

xDCLinkReady

Data type: BOOL

  • TRUE: DC link ready
  • FALSE: DC link not ready

xPowered

Data type: BOOL

  • TRUE: The output stage of the device is enabled
  • FALSE: The output stage of the device is inhibited

xReady

Data type: BOOL

  • TRUE: The device is ready for operation
  • FALSE: The device is not ready for operation

xCloseGridContactor

Data type: BOOL

  • TRUE: The line contactor is controlled.
  • FALSE: The line contactor is not controlled.

xPrechargeActive

Data type: BOOL

  • TRUE: The device is precharging the DC link.
  • FALSE: The device is not precharging the DC link.

xPrechargeLockInactive

Data type: BOOL

  • TRUE: The precharge lock via the digital input is not active. The device can precharge the DC link if required.
  • FALSE: The precharge lock via the digital input is active. The device is therefore not ready for operation and is inhibited.

xRecoveryDisabled

Data type: BOOL

  • TRUE: The recovery function is deactivated, the device can no longer feed back into the grid.
  • FALSE: The recovery function is activated, the device can feed back into the grid. (Depending on selected mode/FCB)

xStandbyActive

Data type: BOOL

  • TRUE: Standby mode activated
  • FALSE: Standby mode deactivated