Preliminary work and tools for startup with keypad or with PC

  • Connect the supply system and the motor. Do not connect signal terminals to prevent the inverter from receiving an enable signal!
  • Switch on the power supply system.
  • The display shows Stop.
  • Program the signal terminals.
  • Set the parameters (e.g. ramps).
  • Check the terminal assignment that has been set (P601 – P622).
  • Switch off the power supply system.
  • Connect the signal terminals.
  • Switch on the power supply system.

 

INFORMATION

The inverter automatically changes parameter values once you perform a startup.