Error 119 MOVIKIT® – MultiMotion additional functions

Error: 119.0 (7700hex | 30464dec)

Description: Interface not linked

 

 

Cause

Measure

Internal fault

Contact SEW-EURODRIVE Service.

Error: 119.1 (7701hex | 30465dec)

Description: Invalid input parameter

 

 

Cause

Measure

One or more input parameters are invalid.

Check that the input parameters are within the limits.

Error: 119.2 (7702hex | 30466dec)

Description: Error reading configuration file

 

 

Cause

Measure

Configuration file for "AntiSlosh" add-on not found on memory card of controller.

In MOVISUITE®, select [Data management] in the controller configuration and download the data by clicking "Update configuration data".

Error: 119.3 (7703hex | 30467dec)

Description: Invalid configuration parameter

 

 

Cause

Measure

A configuration parameter for calculating the AntiSlosh profile is invalid.

Select the configuration parameters of the
AntiSlosh profile within the limits.

Error: 119.4 (7704hex | 30468dec)

Description: Invalid curve description

 

 

Cause

Measure

The curve description must be empty before calling the AntiSlosh constructor.

Delete the curve description before calling the AntiSlosh constructor.

Error: 119.31 (771Fhex | 30495dec)

Description: Undefined error

 

 

Cause

Measure

Internal fault

Contact SEW-EURODRIVE Service.