Error 46 MOVISAFE® CS..A

Error: 46.1 (2E01hex | 11777dec)

Description: MOVISAFE® CS..A safety option no longer responding

 

 

Cause

Measure

No synchronization could be performed with the safety option.

– When using a pluggable safety option, check the device assignment of the basic device and the safety option.

– When using a pluggable safety option, check the slot and installation of the safety option.

– Switch the device off and on again.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Error: 46.2 (2E02hex | 11778dec)

Description: Invalid variant

 

 

Cause

Measure

Safety option variant does not match inverter type.

Use the correct safety option variant.

In a double axis of the MOVIDRIVE® modular application inverter, only safety options without an encoder interface may be used.

Use the correct safety option variant.

Error: 46.3 (2E03hex | 11779dec)

Description: MOVISAFE® CS..A safety option no longer responding

 

 

Cause

Measure

Communication between inverter and safety option interrupted.

– When using a pluggable safety option, check the installation.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Safety option has signaled a warning.

– When using a pluggable safety option, check the installation.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Error: 46.50 (2E32hex | 11826dec)

Description: Warning

 

 

Cause

Measure

Safety option has signaled a warning.

Observe the warning of the safety option subcomponent. Identify the exact cause of this warning and take the appropriate measures for elimination.

Error: 46.51 (2E33hex | 11827dec)

Description: Fault

 

 

Cause

Measure

Safety option has detected an error.

Observe the fault code of the safety option subcomponent. Identify the exact cause of this fault message and take the appropriate measures to eliminate the fault.

Error: 46.52 (2E34hex | 11828dec)

Description: System error/data error/critical error

 

 

Cause

Measure

The MOVISAFE® CS..A safety option has detected an error.

Open the error status of the safety option by selecting [Diagnostics] > [MOVISAFE® CS..]. Identify the exact cause of the error message with the highest priority and take the appropriate measures to eliminate the fault.