Status (OUT)

Variable name

Description

xInOvertemperature

Data type: BOOL

  • TRUE: Temperature limit for overtemperature exceeded
  • FALSE: Temperature value within limits

xInUndertemperature

Data type: BOOL

  • TRUE: Temperature limit for overtemperature not reached
  • FALSE: Temperature value within limits

xInOverVoltage

Data type: BOOL

  • TRUE: Overvoltage limit exceeded
  • FALSE: Voltage value within limits

xInWireBreak

Data type: BOOL

  • TRUE: Wire break detected
  • FALSE: No wire break detected

xInStorageError

Data type: BOOL

  • TRUE: Error in energy storage unit
  • FALSE: No error in energy storage unit

rInTemperature and
ilnTemperature

Data type: REAL or INT

Current temperature (floating point value, integer *10-1 or the original AD voltage value for EKS storage unit).