Status (OUT)

Variable name

Description

xStorageConnected

Data type: BOOL

Status of switching on the energy storage unit

  • TRUE: The connected energy storage unit is connected to the DC link
  • FALSE: The connected energy storage device is not connected to the DC link

xSyncActive

Data type: BOOL

Synchronization status of the connected energy storage unit

  • TRUE: Synchronization and connection or disconnection of energy storage unit active
  • FALSE: Synchronization and connection or disconnection of energy storage unit not active

eStorageState

Data type: ENUMERATION

Current activation state of the energy storage unit.

  • UNKNOWN: The energy storage unit is either connected or disconnected. No charge test has been carried out, therefore the switching state of K1 cannot be reliably indicated.
  • CONNECTED: The energy storage unit is connected to the DC link. The result is reliable because a charge test has been performed.
  • DISCONNECTED: The energy storage unit is not connected to the DC link. The result is reliable because a charge test has been performed.