Basic settings
INFORMATION

The availability of the settings fields described below depends on the axis type (standard or virtual).
Parameter designation | Description |
|---|---|
Higher-level MOVIKIT® | |
MOVIKIT® MultiAxisController | Hide settings that are not relevant for this higher-level software module. When activating this function, refer to the manual for the MOVIKIT® MultiAxisController. |
Index: 50000.255 | |
IEC name: – | |
General | |
Activate simulation |
|
Index: 50000.2 | |
IEC name: Inverter.In.xSimulation | |
Non-volatile position |
|
Index: 50000.6 | |
IEC name: – | |
Additional functions | |
Position controller INFORMATION: The Configuration menu becomes visible when activated. | Extend the software module with the ability to perform central positioning control and encoder evaluation. INFORMATION: If this function is activated, additional setting fields for configuring the software limit switches for position controllers are displayed in the Limit switches configuration menu. |
Index: 50000.102 | |
IEC name: _fbController._stConfig.stOptionalModes.xAddonPositionController | |
Anti-sway control INFORMATION: The Configuration menu becomes visible when activated. | Activation or deactivation of the option to configure vibration suppression measures. |
Index: 50010.108 | |
IEC name: _fbController._stConfig.stOptionalModes.xAddonAntiSway | |
Combined encoder evaluation INFORMATION: The Configuration menu becomes visible when activated. | Extend the software module with the ability to perform combined encoder evaluation. By using this function, only encoder 1 is referenced during referencing in FCB 12. INFORMATION: If the "Combined encoder evaluation" function is activated, then the SW limit switches for position controllers must be used because the motor encoder is monitored when using SW limit switches on the inverter. |
Index: 50010.107 | |
IEC name: _fbController._stConfig.stOptionalModes.xAddonAdvancedEncoderEvaluation | |
Expert mode | Display additional setting fields in various configuration menus. The user is responsible for configuring these setting fields correctly. If the expert mode is not used, all setting fields of the expert mode are set to the default value to ensure optimum operation of the software module. |
Index: 50000.106 | |
IEC name: – | |
Interpolation INFORMATION: The Configuration menu becomes visible when activated. | Extend the software module by the ability to generate travel profiles based on the interpolation of curve point tables. |
Index: 50006.50 | |
IEC name: _fbController._stConfig.stOptionalModes.xAddonInterpolation | |
AntiSlosh INFORMATION: The Configuration menu becomes visible when activated. | Extend the software module by the ability to generate optimized travel profiles with oscillation reduction for cyclical movements of liquids. |
Index: 50006.51 | |
IEC name: _fbController._stConfig.stOptionalModes.xAddonAntiSlosh | |
Touchprobe 1 INFORMATION: The Configuration menu becomes visible when activated. | Configure touchprobe 1 of the inverter in such a way that it can be controlled via the software module and the detected value can be read. |
Index: 50000.20 | |
IEC name: – | |
Energy coupling INFORMATION: The Configuration menu becomes visible when activated. | Activate or deactivate the function to couple the software module with a power supply module for exchanging energy data. The actual function is implemented via a software module on the power supply module when it is activated. |
Index: 50100.240 | |
IEC name: – | |
Additional process values of the inverter INFORMATION: See also chapter Additional process values. | Extend the software module by the ability to configure additional process values of the inverter that can then be read or written in the IEC program. |
Index: 50000.103 | |
IEC name: – | |
Additional process values of the inverter (becomes visible when activating the "Additional process values of the inverter" function) | |
Number of additional process values | Number of additional process values of the inverter that are configured and can be read or written in the IEC program. |
Index: – | |
IEC name: – | |
Process data profile | Process data profile required for the current configuration. |
Index: – | |
IEC name: – | |
"Apply process data profile" button | Button to confirm the required process data profile. |
Index: – | |
IEC name: – | |
Tools used | |
Optimization monitor | A visualization is integrated in the IEC Editor that can be used for manual operation of the software module and for optimizing the control technology. |
Index: 50010.110 | |
IEC name: – | |
Apply all suggested values | Overwrite all values in the configuration of the software module to which a suggested value is assigned with the corresponding suggested value. |