Edge detection after STO and power ON
The Edge detection after STO and power on parameter specifies whether the prioritized terminal control is started after the deactivation of the safety sub-function or with a power switch-on by the signal level or by a positive signal edge.
All other states are evaluated only via the signal level.
Parameter | Setting | Meaning |
|---|---|---|
Edge detection after STO and power on | Signal level | The prioritized terminal control is activated as soon as the signal for activating the function is set at a digital input or if the signal is already present. |
Positive | The selection only affects the signal of the direction of rotation enable ("Prioritized terminal control – positive direction of rotation" or "Prioritized terminal control – negative direction of rotation"). |