0x8480-16 – Position control shift factor

Index-Sub

Type

RW

Default

Range of values

Unit

Description

0x8480-16

U16

R/W

12

0 – 24

Position control shift factor

This parameter is used to limit the speed generated during positioning. The smaller the value, the greater the limitation.