0x8480-09 – Target window

Index-Sub

Type

RW

Default

Range of values

Unit

Description

0x8480-09

S32

R/W**

10

-8388608 –

8388607

(user)

Target window

This object specifies a symmetrical range relative to the target position within which the target is considered to have been reached.