Notes on cable routing and shielding – Recommended cable routing

Note the following points for cable routing and cable shielding:

  • Cable selection
    • When selecting cables, observe the recommended connection cables in the product manual > chapter "Technical data" > "Connection cables".
    • You can use unshielded connection cables as line connection cables.
  • Cable shielding
    • Connect the shields of the cables to the metal housing of the unit using the shield clamps of the accessory bag. To do so, expose the shield in the area of the shield contact surface.
    • As an alternative, you can use optionally available EMC cable glands to connect the shield of cables, see "EMC cable glands" chapter.
  • External braking resistor
    • Also observe the notes in chapter "Terminal assignment ...".
  • Observe the permitted bending radii of the cables for cable routing.