Config (ST_Config_LineSpeed)
Variable name | Description |
|---|---|
uiTolerance | Data type – UINT |
Tolerance window in % in which the lrLineSpeedWinder output signal must be located if speed control is active so that the xSetpointReached output signal can be set to "TRUE". Tolerance window = lrSetpointTension ± uiTolerance | |
uiInRangeTime | Data type – UINT |
Duration in ms for how long the lrLineSpeedWinder output signal must be in the tolerance window if speed control is active so that the xSetpointReached output signal is set to "TRUE". | |
uiOutRangeTime | Data type – UINT |
Duration in ms for how long the lrLineSpeedWinder output signal must be outside the tolerance window if speed control is active so that the xSetpointReached output signal is set to "FALSE". | |
xActivateSpeedControl
| Data type – BOOL |
| |
uiSwitchOnDelay | Data type – UINT |
Switch-on delay of the closed-loop speed control in ms | |
stPID | Data type – ST_Config_PID |
stGeneral | Data type – ST_Config_General |