Additional diagnostic data
The following additional diagnostic data supports startup and facilitates troubleshooting during operation:
- Feedback contacts of the switching elements – The feedback contacts of the switching elements of the energy storage synchronization and the multi-stage fuse concept are provided as a bit field on PI X+1.
- Error response of current error – Each error has a stored error response. This error response of the current error is provided on PI X+2. For further information, refer to chapter Error Manager (ErrorManager).
- Remaining runtime error response – Remaining runtime of the current error response (if the output stage is inhibited with a delay or the storage unit is disconnected with a delay) is provided on PI X+3. If the time has expired or there is no delay, 0 is returned.
- Selected error – The error that was selected in the error list under the selected list index is provided via PI X+4. The selection is also made for PI X+4 for the setpoints.
- Maximum storage temperature – The highest storage temperature known to storage monitoring is provided via PI X+5. This temperature is also provided via the user interface.
- Current consumer power – The sum of all consumer powers known to power monitoring is supplied via PI X+6.
Process input data
Word | Bit | Function | |
|---|---|---|---|
PI X+1 | Switching states | 0 | Q1 |
1 | "1": Synchronizing contactor K3 (plus path) | ||
2 | "1": Synchronizing contactor K1 (minus path) | ||
3 | "1": Bypass contactor K2 | ||
4 | Reserved | ||
5 | Reserved | ||
6 | Reserved | ||
7 | Reserved | ||
8 | Reserved | ||
9 | Reserved | ||
10 | Reserved | ||
11 | Reserved | ||
12 | Reserved | ||
13 | Reserved | ||
14 | Reserved | ||
15 | Reserved | ||
PI X+2 | Error response of the current error |
| 10, 20, 30, 40 See Error responses |
PI X+3 | Remaining runtime error response |
| Remaining runtime until the output stage is inhibited and/or the storage unit is disconnected in [s] |
PI X+4 | Selected error |
| Error in the error chain of the pending errors whose index is selected for the setpoints. If 0, the first error that occurred is displayed. |
PI X+5 | Maximum storage temperature |
| Maximum of all measured individual module temperatures of the additional function "Storage monitoring" in [10-1 °C] |
PI X+6 | Sum of all consumer powers |
| Sum of all power ratings of the consumers (MDS, MDA, etc.) In [10-1 W] |
Process output data
Word | Bit | Function | |
|---|---|---|---|
PO X+1 | Reserved | 0 | Reserved |
1 | Reserved | ||
2 | Reserved | ||
3 | Reserved | ||
4 | Reserved | ||
5 | Reserved | ||
6 | Reserved | ||
7 | Reserved | ||
8 | Reserved | ||
9 | Reserved | ||
10 | Reserved | ||
11 | Reserved | ||
12 | Reserved | ||
13 | Reserved | ||
14 | Reserved | ||
15 | Reserved | ||
PO X+2 | Set test error |
| Set an error response 10, 20, 30 or 40. This can trigger a corresponding error. This error has its own test error code. |
PO X+3 | Reserved | ||
PO X+4 | Error selection |
| Error in the error chain of the pending errors whose index is selected for the setpoints. If 0, the first error that occurred in time is displayed. |
PO X+5 | Reserved | ||
PO X+6 | Reserved | ||