Error Manager
Parameter group | Description |
|---|---|
Basic settings | |
Delay time of output stage inhibit of power supply module | For the error response "Immediate energy storage disconnection (30)", you can set the time after which the output stage of the MDP92A/MDE90A is inhibited using the "Delay time of output stage inhibit of power supply module". This function is useful, for example, for moving the system to a safe position after disconnecting the energy storage unit. MDP92A/MDE90A allows the DC link to be actively charged for the set time. After the set time, the output stage is also inhibited so that no active energy flow is possible. This time should be set specific to the application so that the system can still be moved to a safe position if an error occurs with this error response. |