Status (OUT)

The status of the operating mode is output via the following output variables.

INFORMATION

The submodes displayed in uiActMode are the same as the respective manual modes in terms of their function. The "state of charge control" operating mode is active when the value is "500".

Variable name

Description

rActualVoltage

Data type – REAL

Current voltage of the DC link [V]

rActualEnergy

Data type – REAL

Current amount of energy in the DC link [Ws]

uiActMode

Data type – UINT

Currently activated submode. Submodes are based on manual operating modes, such as "state of charge control" or "DC synchronization".

xRunning

Data type – BOOL

  • TRUE – Operating mode is active
  • FALSE – Operating mode is not active

xReadyForStartup

Data type – BOOL

  • TRUE – DC link is ready for normal operation
  • FALSE – DC link is not fully precharged