Basic settings

 

Parameter name

Description

General

Activate simulation

  • Yes – Simulate axis functions
  • No – Do not simulate axis functions

Index: 50000.2

IEC name: Inverter.In.xSimulation

Functions used

Position controller

 

INFORMATION: The Configuration menu becomes visible when activated.

Activate or deactivate the functions for central position control and encoder evaluation

Index: 50000.102

IEC name: _fbController._stConfig.stOptionalModes.xAddonPositionController

Energy coupling

 

INFORMATION: The Configuration menu becomes visible when activated.

Activate or deactivate the function to couple the software module with a power supply module for exchanging energy data. The actual function is implemented via a software module on the power supply module when it is activated.

Index: 50100.240

IEC name: –

Anti-sway control

 

INFORMATION: The Configuration menu becomes visible when activated.

Activate or deactivate the function to configure oscillation-suppressing measures

Index: 50010.108

IEC name: _fbController._stConfig.stOptionalModes.xAddonAntiSway

Combined encoder evaluation

 

INFORMATION: The Configuration menu becomes visible when activated.

Activate or deactivate the function for combined encoder evaluation

Index: 50010.107

IEC name: _fbController._stConfig.stOptionalModes.xAddonAdvancedEncoderEvaluation

Extended synchronous operation function

 

INFORMATION: The Configuration menu is expanded when activated.

Activate or deactivate additional synchronization/desynchronization modes, an offset correction, an adjust function, and extended gearing status information.

  • Off
  • Synchronize/desynchronize directly to the master. Synchronization/desynchronization only makes sense when in idle state.
  • Extended synchronous operation

Index: 50041.2

IEC name: –

Variable jerk

Activate or deactivate the function for variable presetting of the jerk.

INFORMATION: When using the additional function, refer to the more detailed information in chapter Variable jerk.

Index: 50040.100

IEC name: –

Brake test

Activate or deactivate the function for using the FCB 21 brake test drive function.

INFORMATION: When using the additional function, refer to the more detailed information in chapter Brake test.

Index: 50000.105

IEC name: –

Variable gear ratio master/slave

Activate and or deactivate the function to specify the gear ratio between master and slave via process data.

INFORMATION: When using the additional function, refer to the more detailed information in chapter Variable gear ratio master/slave.

Index:

IEC name: –

Access control

 

INFORMATION: Only visible with "Advanced" permission level.

Activate and/or deactivate the function for separating the axis group when using the MOVIKIT® MultiAxisController and independently moving the axis via the fieldbus interface.

Index: 50000.108

IEC name: –

Touchprobe 1

 

INFORMATION: The Configuration menu becomes visible when activated.

Activate or deactivate the function for reading the detected position and the trigger counter in the event of a trigger event. Together with the "Touchprobe positioning absolute" operating mode, it is also possible to position to a specified position relative to the touchprobe position during a trigger event. For further information, refer to chapter Touchprobe 1.

Index: 50000.20

IEC name: –

Additional process values of the inverter

 

INFORMATION: See also Additional process values of the inverter.

Activate or deactivate the function for configuring additional process values (process input data) of the inverter. Afterwards, they are transferred via the fieldbus interface.

Index:

IEC name: –

"Update configuration data" button

Button for updating the configuration data.

Index:

IEC name: –