On-the-fly synchronization/desynchronization (modulo axis)
On-the-fly synchronization
When using a modulo master, the saw starts during on-the-fly synchronization when the master has reached the configured reference position. The saw is then synchronous after the specified synchronization distance.

On-the-fly desynchronization
When using a modulo master, the saw stops during on-the-fly desynchronization when the master has reached the configured reference position. The saw is then in its starting position.