Touchprobe 1

Parameter name

Description

General

Touchprobe source

Selection of the touchprobe source:

  • Inverter
  • Configured axis
  • User program

Index: 50008.1

IEC name: -

Mode

Selection of the touchprobe mode:

  • Single
  • Multiple

Index: 50008.2

IEC name: TouchProbe.Config.eTouchProbeMode

Trigger

Source

Source for activating the trigger for recording a signal

Index: 8352.10

IEC name: -

Event

Selection of the type of edge used for triggering:

  • Rising edge
  • Falling edge
  • Rising and falling edge

Index: 8352.11

IEC name: -

Sensor dead time rising edge

Dead time of the sensor used for the rising edge at the trigger input. This time will be included in the calculation of the touchprobe result value.

Index: 8352.12

IEC name: Parameter.TouchProbe1.TriggerSensorDeadTimeRisingEdge

Sensor dead time falling edge

Dead time of the sensor used for the falling edge at the trigger input. This time will be included in the calculation of the touchprobe result value.

Index: 8352.13

IEC name: Parameter.TouchProbe1.TriggerSensorDeadTimeFallingEdge

Counter

Counter of trigger events. This value is incremented by the value 1 with each trigger event.

Index: 8352.14

IEC name: Parameter.TouchProbe1.TriggerCounter

Data source

Data source

Data source for trigger recording

Index: 8352.30

IEC name: -

PO data format

Selects the format of the process data:

  • 16 bit
  • 32 bits – big endian
  • 32 bits – little endian

The data format is specified when accessing the PO data words. PO data words have a width of 16 bits and can be combined to a 32-bit value using the PO data format. This parameter has no effect for data sources with a word width of 32 bits.

Index: 8352.31

IEC name: -

Process data –

modulo minimum

Modulo minimum of the source. Is required only if the data source is to be recorded at the time of the modulo change.

Index: 8352.32

IEC name: -

Process data –

modulo maximum

Modulo maximum of the source. Is required only if the data source is to be recorded at the time of the modulo change.

Index: 8352.33

IEC name: -

Process data – dead time

Setting to compensate for the runtime of the process data

Index: 8352.34

IEC name: -

Process data – cycle time

Setting to compensate for the runtime of the process data

Index: 8352.35