Mounting the drive unit
Mount the drive unit on the shaft as follows:
- Perform the steps according to chapter Installation notes.
- Apply NOCO-FLUID® and distribute it carefully.
- Install the shaft and secure it in an axial manner (installation is facilitated by using a fitting tool). The 3 installation types are described below:
- 3A: Standard scope of delivery
- 3B: Assembly/disassembly kit for customer shaft with contact shoulder. For further information, refer to the product manual > chapter Design notes for gear units with hollow shaft and key.
- 3C: Assembly/disassembly kit for customer shaft without contact shoulder. For further information, refer to the product manual > chapter Design notes for gear units with hollow shaft and key.
- Tighten the retaining screw with the specified torque (see "Tightening torques for retaining screws" chapter).
[1] | Short retaining screw (standard scope of delivery) |
[2] | Lock washer |
[3] | Washer |
[4] | Retaining ring |
[6] | Customer shaft |
[1] | Retaining screw |
[2] | Lock washer |
[3] | Washer |
[4] | Retaining ring |
[6] | Customer shaft with contact shoulder |
[1] | Retaining screw |
[2] | Lock washer |
[3] | Washer |
[4] | Retaining ring |
[5] | Spacer tube |
[6] | Customer shaft without contact shoulder |