STO bridging plug (3-phase)

WARNING

Safe disconnection of the device is not possible when the jumper plug is used.
Severe or fatal injuries.
  • Only use the jumper plug if the device is not used to fulfill any safety function.

WARNING

Disabling of the safety-related disconnection of further devices due to parasitic voltages when using an STO jumper plug.
Severe or fatal injuries.
  • Only use the STO jumper plug when all incoming and outgoing STO connections have been removed from the device.

A printed red tag is attached to the STO jumper plug.

The STO jumper plug can be connected to the STO plug connector X5504 of the device. The STO jumper plug deactivates the safety functions of the device.

The following figure shows the STO jumper plug with the printed red tag, part number 28105419: