DC link/energy storage unit does not discharge
Problem
The DC link or energy storage unit does not discharge.
Remedy
- Check that the maximum continuous power of the braking resistor and the correct resistor value in ohms are configured.
- The configuration of the maximum continuous power can be viewed in the configuration of the software module in the "Operating modes" configuration menu in the "Energy storage discharge" submenu.