Required information and configuration data
The following information of the data source is required:
- Signal
- 1st derivation of the signal
- 2nd derivation of the signal (optional)
- Modulo minimum
- Modulo maximum
- Time base of the 1st derivation
- Time base of the 2nd derivation
- Number of decimal places
The following configuration data is required for the cam track:
- Dead time
- Hysteresis
- Switching level
- Acceleration compensation (only possible with 2nd derivation of the signal)
The following configuration data is required for the cam windows:
- Right limit
- Left limit
- Activation direction
- Switching time