Required information and configuration data

The following information of the data source is required:

  • Signal
  • 1st derivation of the signal
  • 2nd derivation of the signal (optional)
  • Modulo minimum
  • Modulo maximum
  • Time base of the 1st derivation
  • Time base of the 2nd derivation
  • Number of decimal places

 

The following configuration data is required for the cam track:

  • Dead time
  • Hysteresis
  • Switching level
  • Acceleration compensation (only possible with 2nd derivation of the signal)

 

The following configuration data is required for the cam windows:

  • Right limit
  • Left limit
  • Activation direction
  • Switching time