Positioning mode: Absolute

Absolute positioning of an axis with reference to machine zero (reference point). The table position is processed with sign.

  • "Linear" axis type: Setpoint position with processing of signs
  • "Modulo" axis type: Setpoint position = modulo min. ≤ target position < modulo max.
  • NOTICE! The specified setpoint position should be smaller than modulo max.

For activation, use the following Module configuration:

Operating mode

Positioning mode

Positioning mode

0: Absolute

Additional mode

0: None